Page 1071 - Softbound_Edition_19_en
P. 1071

Proportional
                                                                                Proportional pressure reducing valve
 pressure reducing valves                                                      Proportional pressure reducing valve


 DIMENSIONS / SECTIONAL DRAWINGS  Proportional pressure reducing cartridge   M33 x 2
 With analog interface  Cavity drawing acc. to  ◆  pilot operated
 ISO 7789–33–04–0–98  ◆  Q  = 160 l/min                          ISO 7789
                max
 40  21, 22  25, 30   p  = 400 bar
 M33x2       ◆  max                                              x II 2 G Ex db IIC T6, T4
             ◆  p    = 350 bar
                N red max                                        x II 2 D Ex tb III C T80 °C, T130 °C
 X2  X2
                                                                 x I M2 Ex db I Mb
 X1  X1                                                          Class I Division 1
 40  21, 22  25, 30                                              Class I Zone 1
 50  60  70
 83  80  90  83  X3  (3)
 X2  15  X2                                                      APPLICATION
            DESCRIPTION
 X1  X1  (2)  Pilot  operated  proportional  pressure  reducing  valve  in  screw-in   These  valves  are  suitable  for  applications  in  explosion-hazard
 A(1)  35   cartridge construction for cavity according to ISO 7789. Proportio-  areas, open cast and also in mines. The electrical remote control in
              A(1)
 35
  83   50  60  90   83   nally to the solenoid current, the solenoid force and the pressure in   conjunction  with  process  controls  allows  economical  solutions
 17.5  X4(nur Regler)  80  70  X3  17.5
 15  (1)    port A (1) rise. The valve functions practically independently of the   with repeatable processes. The screw-in cartridge is perfectly sui-
 s32  M33x2  T(3)  P(2)  T(3)  P(2)  pressure in port P (2). Pressure increase in the consumer port A (1)   table for installation in control blocks and is installed in sandwich-
 17  18  Ø 40
 35   20  103  A(1)  35   (1)  98  A(1)  78  to above the adjusted value, e.g. through an active consumer, is   (vertical stacked systems) and in flange plates (corresponding data
                                                                 sheets in this register). For machining the cartridge cavity in steel
            avoided by discharging excess oil to the tank T (3). With the sole-
  17.5      143  221   17.5   (78)     For detailed cavity drawing  176  noid deenergised, the oil flows freely from port P (2) to consumer   and aluminum blocks, cavity tools are available (hire or purchase).
  M33x2
  s32
  s32      40    M33x2   T(3)  P(2)  see data sheet 2.13-1040  port  A  (1).  For  the  control,  Wandfluh  proportional  amplifiers  are   Please refer to the data sheets in register 2.13.
 40
 P(2)
 T(3)

 17
 18
 40  21, 22  25, 30  With fieldbus interface                    available  (see  register  1.13).  The  pressure  tight  encapsulated
 20   103
  143    78    98   Ex-protection  solenoid  coil  prevents  an  explosion  on  the  inside
  121
 X2   221   X2  With fieldbus interface   78   penetrating to the outside as well as an ignitable surface tempera-
 A(1)  Controller   199   ture.
 X1  X1
            SYMBOL                                               CERTIFICATES
 50  60  70
 83  80  90  83  X3  X2                                                        Surface   Mining  Standard   M248
 15  X1             (A) 1                                                                         -25 °C   Electronic
 A(1)
 P(2)  T(3)                                                                                        to…
 A(1)  A(1)  X3
 35  Analog  35   101                                             ATEX           x         x        x        x
 17.5  17.5  P(2) T(3)  X4(nur Regler)  (P) 2  (T) 3              IECEx          x         x        x        x
 s32  M33x2  T(3)  P(2)  T(3)  P(2)                               CCC            x         x        x        x
 17  18  Ø 40                                                     EAC            x         x        x        x
 20  103  98  78
 143  (78)  176  35                                               Australia      x         x        x
 221  PARTS LIST   17.5                                           MA                       x        x        x
 Position  Article  Description                                   UL / CSA       x                  x
 15  253.8000  HB 4,5 Manual override (data sheet 1.1-300)       The certificates can be found on www.wandfluh.com
 17  160.2187  O-ring ID 18,72 x 2,62 (NBR)
 18  160.2170  O-ring ID 17,17 x 1,78 (NBR)  GENERAL SPECIFICATIONS      ACTUATION
 A(1)  ACCESSORIES
 20  154.2700  Knurled nut  Line mount body   Data sheet 2.9-210  Designation  Proportional pressure reducing valve  Actuation  Proportional solenoid, wet pin push
 21  223.1317  Dummy plug M16 x1,5  Construction  Pilot operated                     type, pressure tight
 22  160.6131  O-ring ID 13,00 x1,5  • Set-up software   see start-up  Mounting  Screw-in cartridge construction  Execution  MKY45 / 18x60 (data sheet 1.1-183)
 25  062.0102  Cover square  • Cable to adjust the settings through  Nominal size  M33 x 2 according to ISO 7789  MKU45 / 18x60 (data sheet 1.1-184)
 30  072.0021  Gasket 33,2 x 59,9 x 2    interface USB   article no. 219.2896  Connection  Cable gland for cable Ø 6,5…14 mm
   (from plug type A to Mini B, 3 m)
 P(2)  T(3)  40  208.0100  Socket head cap screw M4 x10  •  Mating connector (plug female) for the analogue interface:  Actuation  Proportional solenoid
 50  160.2298  O-ring ID 29,82 x 2,62 (NBR)    – straight, soldering contact    article no. 219.2330  Ambient temperature  Operation as T6  Attention!  The UL execution is always supplied without cable
 160.6296  O-ring ID 29,82 x 2,62 (FKM)    – soldering contact   article no. 219.2331  -25…+40 °C (L9)  gland
 60  160.2235  O-ring ID 23,47 x 2,62 (NBR)    Recommended cable size:  Operation as T4
 160.6235  O-ring ID 23,47 x 2,62 (FKM)    – Outer diameter 9…10,5 mm  -25…+90 °C (L9)
 70  160.2219  O-ring ID 21,89 x 2,62 (NBR)    – Single wire max. 1 mm 2  -25…+70 °C (L15 / L17)
   – Recommended wire size:
 160.6216  O-ring ID 21,89 x 2,62 (FKM)      0…25 m = 0,75 mm (AWG18)  Weight  2,4 kg
 2
 80  049.3297  Backup ring RD 24,5 x 29 x 1,4      25…50 m = 1 mm (AWG17)  MTTFd  150 years
 2
 90  049.3277  Backup ring RD 22,5 x 27 x 1,4
 Technical explanation see data sheet 1.0-100


 Wandfluh AG   Tel.  +41 33 672 72 72   E-mail:  sales@wandfluh.com   Illustrations not obligatory   Data sheet no.