P. 1069

21, 22
 40
 25, 30
 X2
 X1
 60
                  X3
 83
 15
 35
 17.5
 s32  M33x2  50  T(3)  80 P(2)  90 A(1) 70  83  17.5  X1  35  X2  T(3)  P(2)  A(1)
 17  18  Ø 40
 20  103                98                   78
 143  (78)                       176
 221  Proportional                                                                                     Proportional
                                                                                          pressure reducing valves
 pressure reducing valves                                                      Proportional pressure reducing valve
 GENERAL SPECIFICATIONS  SYMBOL  NOTE!                           Additional information can be found on our website:
 Description   Pilot operated proportional pressure   Detailed electrical characteristics and description of «DSV»   «www.wandfluh.com»
    reducing valve with integrated electronics  A(1)  electronics are shown on data sheet 1.13-76.
 Construction   Screw-in cartridge for cavity acc. to ISO 7789   Free-of-charge download of the «PASO»-software and the instruction
 Operations   Proportional solenoid, wet pin push type,          manual for the «DSV» hydraulic valves as well as the operation instruc-
    pressure tight  START-UP                                     tion CANopen eg.Profibus DP protocol with device profile DSP-408
 Mounting   Screw-in thread M33x2  For DSV amplifiers as a rule no parameter settings by the customer   for «DSV».
 Ambient temperature  -20…+65 °C (typical)  are required. The plugs have to be connected in accordance with the
            chapter «Pin assignment».
 (The upper temperature limit is a guideline value for typical
 applications, in individual cases it may also be higher or lower.   P(2)  T(3)  NOTE!
 The electronics of the valve limit the power in case of a too   Controllers are delivered configurated as amplifiers. Setting the con-
 high electronics temperature. More detailed information can be   troller mode and adjustment of the controller are carried out by the   The mating connectors and the cable to adjust the settings
 obtained from the operating instructions «DSV».)  CONNECTOR WIRING DIAGRAM  are not part of the delivery. Refer to chapter «Accessories».
 Mounting position   any, preferably horizontal  Analog interface:  customer by means of the software adjustment (USB interface, Mini
 Fastening torque   M  = 80 Nm for screw-in cartridge  B).
 D
    M  = 5 Nm for knurled nut  Device receptacle (male) X1
 D
 Weight   m  = 1,35 kg  CHARACTERISTICS Oil viscosity υ = 30 mm /s
                                             2
 1  =  Supply voltage +  p  = f (Q)  Pressure volume flow characteristics   p  = f (Q)  Pressure volume flow characteristics
 HYDRAULIC SPECIFICATIONS  8 9  1  2  =  Supply voltage 0 VDC     red  (Maximal adjustable pressure)      red  (Minimal adjustable pressure)
 Fluid   Mineral oil, other fluids on request  3  =  Stabilised output voltage     ∗ Consumption resistance dependent on system
 Contamination efficiency   ISO 4406:1999, class 18/16/13  7 12 10 2  4  =  Preset value voltage +
    (Required filtration grade ß 6…10≥75)  6  11 3  5  =  Preset value voltage -  p [bar]  p [bar]
    refer to data sheet 1.0-50/2  8 9  1  5  4  6  =  Preset value current +  400  K0658_1  32  K0659
 2
 2
 1
 Viscosity range   12 mm /s…320 mm /s  7  =  Preset value current -  P N red = 350 bar
 8 9
 Fluid temperature   -20…+70 °C  7 12 10 2  8  =  Reserved for extensions  300  P N red = 275 bar  24
 7 12 10 2
 Peak pressure   p max   = 400 bar  6  11 3  9  =  Reserved for extensions  200  16
 11 3
 6
 Nominal pressure ranges   p N red  = 100 bar, p N red  = 200 bar, 5  4  10 =  Enable control (Digital input)  P N red = 200 bar
 4
 5
    p N red  = 350 bar  2  3  11  =  Error signal (Digital output)  100  8                              ∗
 Volume flow range   Q = 0…160 l/min  5  12 =  Chassis  P N red = 100 bar
 Pilot- and leakage  1  4  0                                       0
 volume flow   see characteristics  Preset value voltage (PIN 4/5) resp. current (PIN 6/7) are selected with   160 120   80   40   0   40   80  120  160  160 120   80   40   0   40   80  120  160
 Repeatability   ≤ 2%  ∗  2  3  set-up and diagnosis software PASO.  2  3  A     T  Q [l/min]  P   A  A     T  Q [l/min]  P   A
 8 9
 1
 Hysteresis   ≤ 4%  ∗  5  Factory setting: Voltage (0…+10 V), (PIN 4/5)  p  = f (s)  Pressure adjustment characteristics
 5
    ∗  at optimal dither signal  1  4  7 12 10 2  1  4     red  [at Q = 0 l/min] / (s corresponds to preset value signal)  Q st + L  = f (p ) Pilot- and leakage volume flow characteristic [A (1) → T (3)]
                                                                        red
 6  11 3                                                                3
 4
 5
 ELECTRICAL SPECIFICATIONS  Fieldbus interface:  2  1  p [bar]      Q [cm /min]
 2
 1
                                                                      K0792
                  K4100_1
 Protection class   IP 67 acc. to EN 60 529  Device receptacle supply (male) X1  120  1000
 5
    with suitable mating connector and   3  4  3  4  90  P N red = 100 bar  800
    closed housing cover     MAIN
 Supply voltage   12 VDC or 24 VDC  2  1  2 2  3 1     1 = Supply voltage +  60  600
 Ramps (amplifier only)   adjustable separately up and down      2 = Reserved for extensions 12  2  1  400
 5
 5
 5
    per each solenoid  3  4  1 3 4 4     3 = Supply voltage 0 VDC  30  200
 Command value gene-  Command value speed adjustable     4 = Chassis  3  4  3  4
 rator (controller only)  0                                        0
 2
 Parameterisation    via fieldbus or USB  Device receptacle   Device receptacle  0   10  20  30  40 50 60 70 80 90  100 s [%]  0  50  100  150  200  250  300  350 p [bar]
 3
 5
 Interface   USB (Mini B) for parameterisation  CANopen (male) X3   Profibus (female) X3  p  = f (s)  Pressure adjustment characteristics
    with «PASO» under the closing screw of the housing cover,   1  4     red  [at Q = 0 l/min] / (s corresponds to preset value signal)
    Preset ex-works  CAN      PROFIBUS
 Analog interface:  2  3  1 = not connected       1 = VP  p [bar]
 1
 2
 Device receptacle (male) M23, 12-poles  5  2  1  2 = not connected       2  3  2 = RxD / TxD - N  400  K4100
 Mating connector   Plug (female), M23, 12-pole (not incl. in delivery)  5  3 = CAN Gnd      5  3 = DGND  P N red = 350 bar
 1
 4
 3
 Preset value signal   Input voltage / current as well as signal range     3  4  4 = CAN High  4    1  4  4 = RxD / TxD - P  300  P N red = 275 bar
    can be set by software  5 = CAN Low      5 = Shield  200  P N red = 200 bar
 Fieldbus interface:
 Device receptacle   M12, 4-pole  Parameterisation interface (USB, Mini B) X2  100
 1
 8 9
 supply (male)   Under the closing screw of the housing cover
 Mating connector   Plug (female), M12, 4-pole (not incl. in delivery)  7 12 10 2  0  
 11 3
 6
 Device receptacle  Feedback value interface (sensor)  0   10  20  30  40 50 60 70 80 90  100 s [%]
 CANopen (male)   M12, 5-pole (acc. to DRP 303-1)  2 5  3 5  4
 Mating connector   Plug (female), M12, 5-pole (not incl. in delivery)  1  4  Inlet pressure: p  +10 %
                        N
 Device receptacle  Device receptacle (female) X4 (controller only)  Mesured with closed port A (static conditions).
 Profibus (female)   M12, 5-pole, B-coded (acc. to IEC 947-5-2)
 Mating connector   Cable plug (male), M12, 5-pole, B-coded  1 = Supply voltage (output) +  Factory settings:
    (not incl. in delivery)  2  3  2 = Feedback value signal +  Dither set for optimal hysteresis
 Command value signal  Fieldbus  5  3 = Supply voltage 0 VDC      =  Deadband:  Solenoid switched off
 1  4  4 = Not connected  with command preset value signal < 5 %
 Feedback value inter-   5 = Stabilised output voltage     =  Regulated pressure in port A (1) at 70 % of preset value signal:
 face (sensor) (controller only)        250 bar with pressure range 350 bar
 Device receptacle    M12, 5-pole        192 bar with pressure range 275 bar
 (female)  NOTE!        143 bar with pressure range 200 bar
 Mating connector   Cable plug (male). M12, 5-pole   The mating connector and the parameterisation cable           72 bar with pressure range 100 bar
    (not included in the delivery)  are not included in the delivery. See chapter "Acces-
 Feedback value   Voltage / current to indicate when ordering  2  1  sories").  1
 2
 5
 3
 4
 4
 Wandfluh AG   Tel.  +41 33 672 72 72   E-mail:  sales@wandfluh.com   3 Illustrations not obligatory   Data sheet no.  Wandfluh AG   Tel.  +41 33 672 72 72   E-mail:  sales@wandfluh.com   Illustrations not obligatory   Data sheet no.
 Postfach   Fax  +41 33 672 72 12   Internet:  www.wandfluh.com   Data subject to change   2.3-652E 2/4  Postfach   Fax  +41 33 672 72 12   Internet:  www.wandfluh.com   Data subject to change   2.3-652E 3/4
 CH-3714 Frutigen                   Edition 17 01  CH-3714 Frutigen                                      Edition 17 01