                                                                                         s32 25, 30  M33x2  50  T(3)  80 P(2)  90 A(1) 70  83  17.5  X1  35  X2    T(3)  P(2)   A(1)
                                                                       17          18      Ø 40
                                                                 20            103                                                             98                    78
                                                                          143                       (78)                                                176
                                                                                   221           Proportional                                                                                                                 Proportional
                                                                         Proportional pressure reducing valve                                                                                                    pressure reducing valves
                                                                                     pressure reducing valves
       GENERAL SPECIFICATIONS                               SYMBOL                                                                          NOTE!                                       Additional information can be found on our website:
       Description     Pilot operated proportional pressure                                                                                 Detailed electrical characteristics and description of «DSV»   «www.wandfluh.com»
                       reducing valve with integrated electronics                  A(1)                                                     electronics are shown on data sheet 1.13-76.
       Construction    Screw-in cartridge for cavity acc. to ISO 7789                                                                                                                   Free-of-charge download of the «PASO»-software and the instruction
       Operations      Proportional solenoid, wet pin push type,                                                                                                                        manual for the «DSV» hydraulic valves as well as the operation instruc-
                       pressure tight                                                                                              START-UP                                             tion CANopen eg.Profibus DP protocol with device profile DSP-408
       Mounting        Screw-in thread M33x2                                                                                       For DSV amplifiers as a rule no parameter settings by the customer   for «DSV».
       Ambient temperature  -20…+65 °C (typical)                                                                                   are required. The plugs have to be connected in accordance with the
                                                                                                                                   chapter «Pin assignment».
                       (The upper temperature limit is a guideline value for typical
                       applications, in individual cases it may also be higher or lower.   P(2)  T(3)                                                                                           NOTE!
                       The electronics of the valve limit the power in case of a too                                               Controllers are delivered configurated as amplifiers. Setting the con-
                       high electronics temperature. More detailed information can be                                              troller mode and adjustment of the controller are carried out by the   The mating connectors and the cable to adjust the settings
                       obtained from the operating instructions «DSV».)  CONNECTOR WIRING DIAGRAM                                                                                               are not part of the delivery. Refer to chapter «Accessories».
       Mounting position   any, preferably horizontal       Analog interface:                                                      customer by means of the software adjustment (USB interface, Mini
       Fastening torque   M  = 80 Nm for screw-in cartridge                                                                        B).
                         D
                        M  = 5 Nm for knurled nut           Device receptacle (male) X1
                         D
       Weight           m  = 1,35 kg                                                                                               CHARACTERISTICS Oil viscosity υ = 30 mm /s
                                                                                                                                                                    2
                                                                             1  =  Supply voltage +                                p  = f (Q)  Pressure volume flow characteristics     p  = f (Q)  Pressure volume flow characteristics
       HYDRAULIC SPECIFICATIONS                                 8 9  1       2  =  Supply voltage 0 VDC                               red   (Maximal adjustable pressure)                  red   (Minimal adjustable pressure)
       Fluid                Mineral oil, other fluids on request             3  =  Stabilised output voltage                                                                                     ∗ Consumption resistance dependent on system
       Contamination efficiency   ISO 4406:1999, class 18/16/13  7 12 10 2   4  =  Preset value voltage +
                            (Required filtration grade ß 6…10≥75)  6  11 3   5  =  Preset value voltage -                              p [bar]                                             p [bar]
                            refer to data sheet 1.0-50/2  8 9  1  5  4       6  =  Preset value current +                            400  K0658_1                                         32  K0659
                                 2
                                          2
       Viscosity range      12 mm /s…320 mm /s                               7  =  Preset value current -                                                                  P N red = 350 bar
                                                                                               1
                                                                                          8 9
       Fluid temperature    -20…+70 °C          7 12 10 2                    8  =  Reserved for extensions                           300                                   P N red = 275 bar  24
                                                                                         7 12 10 2
       Peak pressure        p max   = 400 bar    6  11 3                     9  =  Reserved for extensions                           200                                                  16
                                                                                            11 3
                                                                                          6
       Nominal pressure ranges   p N red  = 100 bar, p N red  = 200 bar, 5  4  10 =  Enable control (Digital input)                                                        P N red = 200 bar
                                                                                           5
                                                                                             4
                            p N red  = 350 bar                2  3           11  =  Error signal (Digital output)                    100                                                  8                                    ∗
       Volume flow range    Q = 0…160 l/min                    5             12 =  Chassis                                                                                 P N red = 100 bar
       Pilot- and leakage                                     1  4                                                                    0                                                   0
       volume flow          see characteristics             Preset value voltage (PIN 4/5) resp. current (PIN 6/7) are selected with    160 120   80   40   0   40   80  120  160           160 120   80   40   0   40   80  120  160
       Repeatability        ≤ 2%  ∗             2  3        set-up and diagnosis software PASO.  2  3                                         A     T  Q [l/min]  P   A                         A     T  Q [l/min]  P   A
                                                              8 9
                                                                  1
       Hysteresis           ≤ 4%  ∗             5           Factory setting: Voltage (0…+10 V), (PIN 4/5)                          p  = f (s)  Pressure adjustment characteristics
                                                                                         5
                            ∗  at optimal dither signal  1  4  7 12 10 2                1  4                                          red   [at Q = 0 l/min] / (s corresponds to preset value signal)  Q st + L  = f (p ) Pilot- and leakage volume flow characteristic [A (1) → T (3)]
                                                                                                                                                                                               red
                                                             6  11 3                                                                                                                            3
                                                               5
                                                                 4
       ELECTRICAL SPECIFICATIONS                          Fieldbus interface:  2  1                                                    p [bar]                                             Q [cm /min]
                                                                 1
                                                              2
                                                                                                                                                                                             K0792
                                                                                                                                         K4100_1
       Protection class   IP 67 acc. to EN 60 529         Device receptacle supply (male) X1                                         120                                                1000
                                                               5
                         with suitable mating connector and   3  4         3   4                                                      90                                   P N red = 100 bar  800
                         closed housing cover                            MAIN
       Supply voltage    12 VDC or 24 VDC      2   1        2 2  3 1     1 = Supply voltage +                                         60                                                 600
       Ramps (amplifier only)   adjustable separately up and down        2 = Reserved for extensions 12  2  1                                                                            400
                                                5
                                                            5
                                                                                         5
                         per each solenoid      3  4        1 3 4 4      3 = Supply voltage 0 VDC                                     30                                                 200
       Command value gene-  Command value speed adjustable               4 = Chassis    3   4         3  4
       rator (controller only)                                                                                                         0                                                  0
                                                                 3
                                                             2
       Parameterisation    via fieldbus or USB            Device receptacle            Device receptacle                                0   10  20  30  40 50 60 70 80 90  100 s [%]         0   50  100  150  200  250  300  350 p [bar]
                                                               5
       Interface         USB (Mini B) for parameterisation  CANopen (male) X3          Profibus (female) X3                         p  = f (s)  Pressure adjustment characteristics
                         with «PASO» under the closing screw of the housing cover,   1  4                                              red  [at Q = 0 l/min] / (s corresponds to preset value signal)
                         Preset ex-works                          CAN                         PROFIBUS
       Analog interface:                       2   3              1 = not connected           1 = VP                                   p [bar]
                                                                         2
                                                                            1
       Device receptacle (male) M23, 12-poles   5           2  1  2 = not connected       2  3  2 = RxD / TxD - N                    400  K4100
       Mating connector   Plug (female), M23, 12-pole (not incl. in delivery)  5  3 = CAN Gnd      5  3 = DGND                                                             P N red = 350 bar
                                               1
                                                   4
                                                                         3
       Preset value signal   Input voltage / current as well as signal range     3  4  4 = CAN High  4    1  4  4 = RxD / TxD - P    300                                   P N red = 275 bar
                         can be set by software                   5 = CAN Low                 5 = Shield                             200                                   P N red = 200 bar
       Fieldbus interface:
       Device receptacle   M12, 4-pole                    Parameterisation interface (USB, Mini B) X2                                100
                                                              8 9
                                                                  1
       supply (male)                                      Under the closing screw of the housing cover
       Mating connector   Plug (female), M12, 4-pole (not incl. in delivery)  7 12 10 2                                                0  
                                                             6
                                                                11 3
       Device receptacle                                  Feedback value interface (sensor)                                             0   10  20  30  40 50 60 70 80 90  100 s [%]
       CANopen (male)    M12, 5-pole (acc. to DRP 303-1)   2 5  3 5  4
       Mating connector   Plug (female), M12, 5-pole (not incl. in delivery)  1  4                                                 Inlet pressure: p  +10 %
                                                                                                                                               N
       Device receptacle                                  Device receptacle (female) X4 (controller only)                          Mesured with closed port A (static conditions).
       Profibus (female)   M12, 5-pole, B-coded (acc. to IEC 947-5-2)
       Mating connector   Cable plug (male), M12, 5-pole, B-coded    1 = Supply voltage (output) +                                 Factory settings:
                         (not incl. in delivery)            2  3     2 = Feedback value signal +                                   Dither set for optimal hysteresis
       Command value signal  Fieldbus                        5       3 = Supply voltage 0 VDC                                          =  Deadband:  Solenoid switched off
                                                            1  4     4 = Not connected                                                  with command preset value signal < 5 %
       Feedback value inter-                                         5 = Stabilised output voltage                                    =  Regulated pressure in port A (1) at 70 % of preset value signal:
       face (sensor) (controller only)                                                                                                   250 bar with pressure range 350 bar
       Device receptacle    M12, 5-pole                                                                                                  192 bar with pressure range 275 bar
       (female)                                                       NOTE!                                                              143 bar with pressure range 200 bar
       Mating connector   Cable plug (male). M12, 5-pole              The mating connector and the parameterisation cable                  72 bar with pressure range 100 bar
                         (not included in the delivery)               are not included in the delivery. See chapter "Acces-
       Feedback value    Voltage / current to indicate when ordering  2  1  sories").  1
                                                                         2
                                                             5
                                                               4
                                                            3
                                                                            4
       Wandfluh AG        Tel.  +41 33 672 72 72   E-mail:  sales@wandfluh.com   3 Illustrations not obligatory   Data sheet no.   Wandfluh AG         Tel.  +41 33 672 72 72   E-mail:  sales@wandfluh.com   Illustrations not obligatory   Data sheet no.
       Postfach           Fax  +41 33 672 72 12   Internet:  www.wandfluh.com   Data subject to change   2.3-652E 2/4              Postfach            Fax  +41 33 672 72 12   Internet:  www.wandfluh.com   Data subject to change   2.3-652E 3/4
       CH-3714 Frutigen                                                                            Edition 17 01                   CH-3714 Frutigen                                                                             Edition 17 01
       Page 1068
                                                           2   3
                                                            5
                                                           1   4
   1063   1064   1065   1066   1067   1068   1069   1070   1071   1072   1073