 CHARACTERISTICS  Oil viscosity  ν = 30 mm /s  Proportional pressure reducing cartridge
 2
 p  = f (Q)   Pressure volume flow characteristics   p  = f (Q)   Pressure volume flow characteristics  ◆  pilot operated  7 ⁄8 “-14 UNF
 red
 red
    (Maximal adjustable pressure)     (Minimal adjustable pressure)  ◆  Q  = 60 l/min  Wandfluh standard
                max
 p [bar]  p [bar]  ◆  p  = 400 bar
                max
 60  K0970  16  K0971  ◆  p   = 350 bar
                N red max

 45  12
 P N red = 48 bar
 30  P N red = 25 bar  8
            DESCRIPTION                                          APPLICATION
 15  4      Pilot  operated  proportional  pressure  reducing  valve  in  screw-in   The electrical remote control in conjunction with process controls
            cartridge construction for cavity according to Wandfluh standard.   allows  economical  solutions  with  repeatable  processes.  The
 0  0
 4  3  2  1  0  1  2  3  4  4  3  2  1  0  1  2  3  4  Proportionally to the solenoid current, the solenoid force and the   screw-in cartridge is perfectly suitable for installation in control
 A     T  Q [l/min]  P   A  A     T  Q [l/min]  P   A  pressure in port A (1) rise. The valve functions practically indepen-  blocks. For machining the cartridge cavity in steel and aluminum
            dently of the pressure in port P (2). Pressure increase in the consu-  blocks, cavity tools are available (hire or purchase). Please refer to
  = f (l)   Pressure adjustment characteristics    Q   = f (p )  Pilot- and leakage volume flow characteristice


 p red  st + L  red  mer port A (1) to above the adjusted value, e.g. through an active   the data sheets in register 2.13.
    [at Q = 0 l/min] / (static)     [P (2) → T (3)]  consumer, is avoided by discharging excess oil to the tank T (3).
 p [bar]  Q [cm /min]  With the solenoid deenergised, the oil flows freely from port P (2) to
 3
 60  K0972  160  K0973
            consumer port A (1). For the control, Wandfluh proportional ampli -
 45  P N red = 48 bar  120  fiers are available (see register 1.13).
 P N red = 25 bar
 30  80
 15  40
 0  0
 0   10  20  30  40 50 60 70 80 90  100 l [%]  0  50  100  150  200  250  300  350 p [bar]
 A     T  Q [l/min]  P   A  P N red = 25 bar
 P N red = 48 bar
            SYMBOL                                               ACTUATION
                                                                  Actuation          Proportional solenoid, wet pin push
                    (A) 1                                                            type, pressure tight
                                                                  Execution          W.S37 / 19 x 50 (Data sheet 1.1-173)
 DIMENSIONS / SECTIONAL DRAWINGS  PARTS LIST                                         M.S35 / 19 x 50 (Data sheet 1.1-174)
                                                                  Connection         Connector socket EN 175301 – 803
 20  Position  Article  Description  (P) 2  (T) 3                                    Connector socket AMP Junior-Timer
 15  253.8000  Mounted screw with integrated                                         Connector Deutsch DT04 – 2P
 manual override HB 4,5
 20  219.2002  Plug (black)
 30  160.0060  O-ring ID 6,07 x 1,78
 40  160.0071  O-ring ID 7,65 x 1,78
 15  50  160.2204  O-ring ID 20,35 x 1,78
 50
 74
 40         STANDARDS                                            INSTALLATION NOTES
 30  Cavity drawing acc. to
 T(3)  Wandfluh standard  Cartridge cavity  Wandfluh standard     Mounting type      Screw-in cartridge  ⁄8 “-14 UNF
                                                                                                   7
 A(1)        Solenoids           DIN VDE 0580                     Mounting position  Any, preferably horizontal
 Ø 11        Connection execution D  EN 175301 – 803              Tightening torque  M  = 60 Nm Screw-in cartridge
                                                                                      D
 P(2)
             Protection class    EN 60 529                                           M  = 5 Nm knurled nut
                                                                                      D
             Contamination efficiency ISO 4406                                       M  = 9,5 Nm HB0
                                                                                      D
                                                                                     M  = 5,5 Nm HB4,5
 70,3  14  T(3)                                                                       D
 P(2)
 A(1)

 A(1)
 ACCESSORIES  A(1)
 Proportional amplifier   register 1.13
 For detailed cavity drawing
 Technical explanation see data sheet 1.0-100  see data sheet 2.13-1044