Non-return valve hydraulically pilot operated
Description
Hydraulically pilot operated non-return valve in screw-in cartridge construction for cavity according to ISO 7789. In the free flow direction (2 → 1), the volume flow opens the spring loaded seat cone. In the opposite direction (1 → 2), the spring keeps the valve closed. If pressure is built up in connection x, the pilot control spool is shifted and the non-return valve of the closed off port is opened by this. The required pilot control pressure depends on the pilot ratio.
Application
Pilot operated non-return valves are used for closing off pressurised hydraulic cylinders leak free, for example in lifting or clamping devices. The spool valve that directs the volume flow to port x, should have both service ports connected to the tank in the rest position for reasons of operational safety.
Key facts
Non-return valve hydraulically pilot operated
Screw-in cartridge construction
- Qmax = 150 l/min
- pmax = 350 bar
Contact us now
Do you have questions about this product or need help finding the best solution for your project? Our network of experienced sales experts is here to support you – personally, competently, and close to you.
To the sales network