Page 858 - Softbound_Edition_19_en
P. 858

Pressure relief valve



                                                                                                                                   Pressure relief valve
                                                                                                                                                                                        NG4-Mini
                                                                                                                                   Flange- or Sandwich construction                     Wandfluh standard
                                                                                                                                    ◆  pilot or direct operated
                                                                                                                                    ◆  p  = 400 bar
                                                                                                                                       max
                                                                                                                                    ◆  p N max  = 350 bar
                                                                                                                                    ◆  Q  = 30 l/min
                                                                                                                                       max


                                                                                                                                   DESCRIPTION                                          APPLICATION
                                                                                                                                   Pilot or direct operated pressure relief valve in flange or sandwich   For the limitation of the operating pressure in hydraulic systems by
                                                                                                                                   construction. When  the  adjusted  operating  pressure  is  reached,   reliefing the oil from the secured oil line P (1), A (2), B (3) to output /
                                                                                                                                   the  main  spool  opens  and  connects  the  protected  line  with  the   tank  line  T  (4).  Miniature  values  are  used  where  both,  reduced
                                                                                                                                   drain to the tank. For flange or sandwich executions with pressure     dimensions and weight are important.






                                                                                                                                   relief in port P, there is a manometer connection.
                                                                                                                                   SYMBOL
                                                                                                                                   Flange execution
                                                                                                                                   B..FA04-P                                            Note!    ◆  Direct operated execution drawn
                                                                                                                                                                                                 ◆  All variants are also available pilot operated



                                                                                                                                     A    P      T    B

                                                                                                                                   Sandwich execution       Sandwich execution          Sandwich execution       Sandwich execution
                                                                                                                                   B..SA04-P                B..SA04-A                   B..SA04-B                B..SA04-AB




                                                                                                                                     A    P      T    B       A    P      T    B          A    P      T    B      A    P       T    B






                                                                                                                                   GENERAL SPECIFICATIONS                               ACTUATION
                                                                                                                                    Designation        Pressure relief valve             Actuation          S = lockable key adjustment
                                                                                                                                    Construction       Direct or pilot operated                             D = lockable knob adjustment
                                                                                                                                    Mounting           Flange- or Sandwich construction  Note!   Other specifications, see data sheet of the screw-in
                                                                                                                                    Nominal size       NG4-Mini according to Wandfluh            cartridges
                                                                                                                                                       standard
                                                                                                                                    Actuation          Manually
                                                                                                                                    Ambient temperature  -25…+70 °C
                                                                                                                                    Weight             1,35 kg (Flange construction)
                                                                                                                                                       1,15 kg (Sandwich construction P, A, B)
                                                                                                                                                       1,60 kg (Sandwich construction AB)















                                                                                                                                                      www.wandfluh.com  Illustrations are not binding  Data subject to change  1/3  Edition: 20 44  2.1-620 E