Page 740 - Softbound_Edition_19_en
P. 740

Digital amplifier module
                                                                                  Digital amplifier module SD7
       CONNECTION EXAMPLE ENHANCED AMPLIFIER

       Mode of operation „Command value unipolar (2-sol)“ or „Command value unipolar (2-sol with DigInp)“




                                       Fuse                        Solenoid A              Solenoid B
                        Supply voltage +
                        Supply voltage -


                        Command value preset
                        with potentiometer
                        on analogue input 1                         Error active/  Supply voltage +
                                                                    Solenoid A active
                        Enable                       X1-17                        on Digital input 1
                        on Digital input 3
                                                                    Solenoid B active
                        Solenoid B active
                        (only with mode of operation 5)  X1-18                    on Digital input 2
                        on Digital input 4


                        Ramp off                     X1-19
                        on Digital input 5
                        Fixed command value 1        X1-20
                        Fixed command value 2        X1-21
                        Fixed command value 4        X1-22
                        on Digital input 6–8
                        Disable solenoid A           X1-1
                        Disable solenoid B           X1-2
                        on Digital input 1–2
                                                             Option
                        Option             Fieldbus
                        Command value preset         X4
                        and enable         Master
                        via fieldbus








       CONNECTION EXAMPLE ENHANCED AMPLIFIER WITH HART
       Mode of operation „Command value unipolar (2-sol)“ or „Command value unipolar (2-sol with DigInp)“




                                       Fuse                         Solenoid A             Solenoid B
                          Supply voltage +           X1-5
                          Supply voltage -           X1-6      X1-15
                                                               X1-16

                                                               X1-13
                          Command value preset       X1-21     X1-14
                          and enable      HART       X1-22
                          via HART
                          on analogue input 3                         Error active/  Supply voltage +
                                                                      Solenoid A active
                                                               X1-3               on Digital input 1
                                                                      Solenoid B active
                                                               X1-4               on Digital input 2




                                       Fuse                         Solenoid A
                          Supply voltage +           X1-5
                          Tel.  +41 33 672 72 72
       Wandfluh AG        Supply voltage -        sales@wandfluh.com      Illustrations not obligatory   Data sheet no.
                                                               X1-15
                                                     X1-6
       Postfach           Fax  +41 33 672 72 12   www.wandfluh.com        Data subject to change   1.13-101E 10/10
                                                               X1-16
       CH-3714 Frutigen                                             Solenoid B                     Edition 23 02
       Page 740
                          Command value preset       X1-21
                          and enable      HART       X1-22     X1-14
                          via HART
                          on analogue input 3                          Error active/  Supply voltage +
                                                                      Solenoid A active
                                                               X1-3               on Digital input 1
                                                                      Solenoid B active
                                                               X1-4               on Digital input 2