Proportional spool valve
                                                                                     Proportional spool valve                                                                                                     Proportional spool valve


       TYPE CODE                                                                                                                   ELECTRICAL CONNECTION
                                                                        B  R  W     -     -  24        -     #                      X1                 Analog interface (Main)           X1                 Fieldbus interface (Main)
       Mounting interface according to Wandfluh standard
                                                                                                                                    Device receptacle  M23, 12 pole male                 Device receptacle  M12, 4 pole male
       Integrated electronics, spool position control                                                                                                  1 = Supply voltage +                           2  1  1 = Supply voltage +
                                                                                                                                              8 9  1   2 = Supply voltage 0 VDC                       3 4   2 = Reserved for extentions
       Proportional spool valve                                                                                                              7 12 10 2  3 = Stabilised output voltage                       3 = Supply voltage 0 VDC
                                                                                                                                             6  11 3
                                                                                                                                               5  4    4 = Command value signal voltage +                   4 = Chassis
       Designation of symbols according to table
                                                                                                                                                       5 = Command value signal voltage -
       Nominal volume flow rate Q N   4 l/min   4                                                                                                      6 = Command value signal current +
                              8 l/min       8                                                                                                          7 = Command value signal current -
                                                                                                                                                       8 = Reserved for extentions
       Nominal voltage U      24 VDC                                                                                                                                                     X2                 Parameterisation interface
                   N                                                                                                                                   9 = Reserved for extentions
                                                                                                                                                       10 = Enable signal (Digital input)  USB, Mini B      Under the screw plug of the housing
       Hardware configuration
       Analog command value signal   12 pole   A2   7 pole     D2     (-10 … 10 V preset)                                                              11 = Error signal (Digital output)                   cover
       Analog command value signal   12 pole   A4   7 pole     D4     (4 … 20 mA preset)                                                               12 = Chassis                                         Factory set
       CANopen according to  DSP-408       C1                                                                                       Command value signal voltage (PIN 4/5) resp. current (PIN 6/7) are
       Profibus DP according to Fluid Power Technology   P1                                                                         selected with parameterisation and diagnostics  software PASO.
       CAN J1939 (on request)              J1
       Function
       Amplifier                                                                                                                    X1                 Analog interface (Main)           X3                 Profibus interface according to IEC
       Controller with current feedback value signal (0 … 20 mA / 4 … 20 mA)  R1                                                                       Connector DIN EN 175201 - 804                        947-5-2
       Controller with voltage feedback value signal (0 … 10 V)       R2
                                                                                                                                    Device receptacle  7 pole male                       Device receptacle  M12, 5 pole female B-coded
       Sealing material       NBR                                                                                                                      A = Supply voltage +                           2 3   1 = VP
                                                                                                                                                                                                      5
                              FKM (Viton)                      D1                                                                           F   A  B   B = Supply voltage 0 VDC                       1 4   2 = RxD / TxD - N
                                                                                                                                                G      C = Analog output -                                  3 = DGND
       Design index (subject to change)                                                                                                     E     C
                                                                                                                                                D      D = Command value signal +                           4 = RxD / TxD - P
       1.10-70
                                                                                                                                                       E = Command value signal -                           5 = Shield
                                                                                                                                                       F = Analog output +
       GENERAL SPECIFICATIONS                              HYDRAULIC SPECIFICATIONS                                                                    G = Chassis
       Designation        Proportional spool valve          Working pressure   p  = 315 bar                                         Command value signal: current (D4) or voltage (D2) to specify
                                                                                max
       Construction       Direct operated                   Tank pressure      p  max = 160 bar                                     when placing the order
                                                                                T
       Mounting           Flange construction               Maximum volume flow  Q   = 20 l/min, see characteristics
                                                                                 max
       Nominal size       NG4-Mini according to Wandfluh    Nominal volume flow  Q  = 4 l/min, 8 l/min
                                                                                N
                          standard                          Leakage oil        On request                                           X3                 CANopen interface according to DRP   X4 (controller only)  Feedback value interface (sensor)
       Actuation          Proportional solenoid             Hysteresis         < 0,4 %                                                                 303-1                             Device receptacle  M12, 5 pole female
       Ambient temperature  -20…+65 °C                      Repeatability      < 0,4 %                                              Device receptacle  M12, 5 pole male                               2 3   1 = Supply voltage (output) +
                                                                                                                                                                                                      5
                                                                                                                                                                                                            2 = Feedback value signal +
                                                                                                                                                       1 = Not connected
                          The upper temperature limit is a   Fluid             Mineral oil, other fluid on request                               2 1   2 = Not connected                              1 4   3 = Supply voltage 0 VDC
                                                                                                                                                  5
                          guideline for typical applications, in   Viscosity range  12 mm /s…320 mm /s                                           3 4   3 = CAN Gnd                                          4 = Not connected
                                                                                            2
                                                                                   2
                          individual cases it may also be higher or   Temperature range   -25…+70 °C (NBR)                                             4 = CAN High                                         5 = Stabilised output voltage
                          lower. The electronics of the valve limit   fluid    -20…+70 °C (FKM)                                                        5 = CAN Low
                          the power in case of a too high   Contamination      Class 18 / 16 / 13                                                                                        Feedback value signal: current (R1) or voltage (R2) to specify
                          electronics temperature. More detailed   efficiency                                                                                                            when placing the order
                          information can be obtained from the
                          operating instructions „DSV”.     Filtration         Required filtration grade ß 10…16 ≥ 75,
       Weight             1,95 kg                                              see data sheet 1.0-50                               Note!    The mating connector is not included in the delivery
                                                            Step response      Typical 25 ms from 10% to 90%