Page 360 - Softbound_Edition_19_en
P. 360

Proportional spool valve



                                                                                                                                   Proportional spool valve
                                                                                                                                                                                        NG4
                                                                                                                                   Flange construction                                  ISO 4401-02
                                                                                                                                    ◆  Q  = 20 l/min
                                                                                                                                       max
                                                                                                                                    ◆  3 volume flow levels
                                                                                                                                    ◆  Q N max  = 12 l/min
                                                                                                                                    ◆  p  = 350 bar
                                                                                                                                       max





                                                                                                                                   DESCRIPTION                                          APPLICATION
                                                                                                                                   Direct operated proportional spool valve with 4 connections in   Proportional  spool  valves  are  perfectly  suitable  for  demanding
                                                                                                                                   5-chamber system. Precise spool fit, low leakage, long service   tasks due to the high resolution, large volume flow and low hystere-
                                                                                                                                   life time. The volume flow adjustment takes place by a Wandfluh   sis. The applications are in the industry as well as in the mobile hy-
                                                                                                                                   proportional solenoid. Proportional to the solenoid current, the   draulics for the smooth control of hydraulic actuators. Some ex-
                                                                                                                                   spool  stroke,  the  spool  opening  and  the  valve  volume  flow    amples: rotor blades control of wind generators, forestry and earth
                                                                                                                                   increase. For the control, Wandfluh proportional amplifiers are   moving machines, machine tools and paper production machines
                                                                                                                                   available (see register 1.13).                       with simple position control, robotics and fan control. Miniature
                                                                                                                                                                                        values are used where both, reduced dimensions and weight are

                                                                                                                                                                                        important.


                                                                                                                                   SYMBOL
                                                                                                                                   Symmetrical control
                                                                                                                                                  ACB-S                                AC1-S                       CB2-S

                                                                                                                                                  A  B                                    A  B                   A  B
                                                                                                                                             a      0     b                         a                                   b
                                                                                                                                    a                               b       a                     b        a                      b
                                                                                                                                                  P  T                                    P  T                   P  T

                                                                                                                                   Meter-in control
                                                                                                                                                  ACB-V                                AC1-V                       CB2-V

                                                                                                                                                  A  B                                    A  B                   A  B

                                                                                                                                             a      0     b                         a                                   b
                                                                                                                                    a                               b       a                     b        a                      b
                                                                                                                                                  P  T                                    P  T                   P  T

                                                                                                                                   Meter-in control
                                                                                                                                                  ADB-V                                AD1-V                       DB2-V
                                                                                                                                                  A  B                                    A  B                   A  B

                                                                                                                                             a            b                         a                                   b
                                                                                                                                    a                               b       a                     b        a                      b
                                                                                                                                                  P  T                                    P  T                   P  T

                                                                                                                                   Meter-out control
                                                                                                                                                  ACB-R                                AC1-R                       CB2-R

                                                                                                                                                  A  B                                    A  B                   A  B
                                                                                                                                             a      0     b                         a                                   b
                                                                                                                                    a                               b       a                     b        a                      b
                                                                                                                                                  P  T                                    P  T                   P  T






                                                                                                                                                      www.wandfluh.com  Illustrations are not binding  Data subject to change  1/5  Edition: 17 35  1.10-74 E
   355   356   357   358   359   360   361   362   363   364   365