Page 1174 - Softbound_Edition_19_en
P. 1174

Flow control valves


                                                                                                                                   2-way flow control valve
                                                                                                                                   Fixed orifice, adjustable pressure compensator
                                                                                                                                   Sandwich construction                                    ®
                                                                                                                                   • Q max   = 10 l/min                         NG3-Mini
                                                                                                                                   • Q N max  = 8 l/min
                                                                                                                                   • p    = 315 bar
                                                                                                                                      max
                                                                                                                                   DESCRIPTION                        FUNCTION                           APPLICATION
                                                                                                                                   Sandwich type 2-way flow control valve. Fitted   The  2-way  flow  control  valve  is  designed   Sandwich type flow control valves are used whe-
                                                                                                                                   with 2-way flow control cartridge M18x1,5 in   to  keep  the  speed  of  a  consumer  constant   re the supply volume flow has to be kept constant
                                                                                                                                   accordance with ISO 7789. Type of adjustment   irrespective of the load. The fixed measuring   even when the load fluctuates. Depending on
                                                                                                                                   available: „S“ = screw adjustment, „D“ = knob   orifice which is integrated into the pressure   the application, a distinction is made between
                                                                                                                                   adjustment, (see data sheet no. 2.5-510). For   compensating piston determines the volume   restricting the forward flow or the return flow.
                                                                                                                                   the sandwich plates in A, B and AB, a bypass   flow. If there is a pressure change, the pressure   These sandwich valves are particularly suitable
                                                                                                                                   non-return  valve  for  reversed  free  flow  is   compensating spool is displaced and changes   for machine tools and also all types of handling
                                                                                                                                   installed.                         the outlet diameter in order to keep the pres-  operations. The Mini-3 flow control valves are
                                                                                                                                                                      sure difference across the measuring orifice   used where hydraulic systems have to be both
                                                                                                                                                                      constant.  By  varying  the  spring  bias  acting   light and compact.
                                                                                                                                                                      on the compensator spool, the flow rate can
                                                                                                                                                                      be changed. Minimum adjustable flow within
                                                                                                                                                                      40…70 % of Q . Flow regulation is effective
                                                                                                                                                                                 N
                                                                                                                                                                      above ∆p 10 bar approx.
                                                                                                                                   TYPE CODE

                                                                                                                                                                                                         QA      S  A03  -   -       #
                                                                                                                                   Flow control valve, 2-way
                                                                                                                                   Type of adjustment  Screw   S
                                                                                                                                                  Turning knob  D
                                                                                                                                   Sandwich construction
                                                                                                                                   Mounting interface acc. to Wandfluh standard, NG3-Mini
                                                                                                                                   Type list/Function
                                                                                                                                                          in P       P     in T     T
                                                                                                                                   Meter-out flow control   in A     A     in B     B
                                                                                                                                                          in A and B    AB
                                                                                                                                   Meter-in flow control   in A      AV    in B     BV
                                                                                                                                                          in A and B   ABV
                                                                                                                                   Nominal volume flow rate Q   0,4...0,6 l/min   0,63
                                                                                                                                                       N
                                                                                                                                                        0,8...1,25 l/min   1,25
                                                                                                                                                         1,3...2,1 l/min   2
                                                                                                                                                          2,5...5 l/min   5
                                                                                                                                                           5 ...8 l/min   8
                                                                                                                                   Design index (subject to change)

                                                                                                                                   GENERAL SPECIFICATIONS                               HYDRAULIC SPECIFICATIONS
                                                                                                                                   Description      2-way flow control valve            Fluid               Mineral oil, other fluid on request
                                                                                                                                   Nominal size      NG3-Mini acc. to Wandfluh standard  Contamination efficiency  ISO 4406:1999, class 18/16/13
                                                                                                                                   Construction      Sandwich                                               (Required filtration grade ß 6...10 ≥ 75)
                                                                                                                                   Mounting         3 mounting holes for socket head screws                 refer to data sheet 1.0-50/2
                                                                                                                                                    M  4   or double ended screws M4    Viscosity range     12 mm /s...320 mm /s
                                                                                                                                                                                                                 2
                                                                                                                                                                                                                         2
                                                                                                                                   Connections      Threaded connection plates, Multi-flange   Fluid temperature   -20...+70 °C
                                                                                                                                                    subplates, Longitudinal stacking system  Peak pressure       p  max  = 315 bar
                                                                                                                                   Ambient temperature   -20…+50 °C                     Opening pressure
                                                                                                                                   Mounting position   any                              to non-return valve   p  = 0,2 bar
                                                                                                                                                                                                             ö
                                                                                                                                   Fastening torque   M = 2,8 Nm (quality 8.8) for fastening screws  Minimum pressure for
                                                                                                                                                      D
                                                                                                                                                    M  D  = 30 Nm for screw-in cartridge   controlled flow     ∆p = 10 bar
                                                                                                                                   Weight           depending on the type 0,32…0,42 kg  Nominal volume flow   Q = 0,63 l/min, Q = 1,25 l/min,
                                                                                                                                                                                                             N
                                                                                                                                                                                                                        N
                                                                                                                                                                                                            Q  N = 2 l/min, Q = 5 l/min,Q = 8 l/min
                                                                                                                                                                                                                      N
                                                                                                                                                                                                                              N
                                                                                                                                                                                        Min. volume flow    Q  = 0,4 l/min
                                                                                                                                                                                                             min
                                                                                                                                                                                        Max. volume flow    Q max  = 10 l/min
                                                                                                                                                                                        Hysteresis          depending on nominal volumeflow 3...8 %
                                                                                                                                                                                        For further hydraulic specifications refer to data sheet 2.5-510.

                                                                                                                                   Wandfluh AG         Tel.  +41 33 672 72 72   E-mail:  sales@wandfluh.com   Illustrations not obligatory   Data sheet no.
                                                                                                                                   Postfach            Fax  +41 33 672 72 12   Internet:  www.wandfluh.com   Data subject to change   2.5-700E 1/2
                                                                                                                                   CH-3714 Frutigen                                                                             Edition 21 31
   1169   1170   1171   1172   1173   1174   1175   1176   1177   1178   1179