Page 366 - Softbound_Edition_19_en
P. 366

Proportional spool valve



                                                                                                                                   Proportional spool valve
                                                                                                                                                                                        NG6
                                                                                                                                   Flange construction                                  ISO 4401-03
                                                                                                                                    ◆  Q  = 42 l/min
                                                                                                                                       max
                                                                                                                                    ◆  4 volume flow levels
                                                                                                                                    ◆  Q N max  = 32 l/min
                                                                                                                                    ◆  p  = 350 bar
                                                                                                                                       max


                                                                                                                                   DESCRIPTION                                          APPLICATION
                                                                                                                                   Direct  operated  proportional  spool  valve  with  4  connections  in   Proportional  spool  valves  are  perfectly  suitable  for  demanding
                                                                                                                                   5-chamber system. Precise spool fit, low leakage, long service life   tasks due to the high resolution, large volume flow and low hyste-
                                                                                                                                   time.  The  volume  flow  adjustment  takes  place  by  a  Wandfluh   resis. The applications are in the industry as well as in the mobile
                                                                                                                                     proportional  solenoid.  Proportional  to  the  solenoid  current,  the   hydraulics  for  the  smooth  control  of  hydraulic  actuators.  Some
                                                                                                                                   spool stroke, the spool opening and the valve volume flow increase.     examples: control of the rotor blades of wind generators, forestry
                                                                                                                                   For the control, Wandfluh proportional amplifiers are available (see   and earth moving machines, machine tools and paper production


                                                                                                                                   register 1.13).                                      machines, simple position controls, robotics and fan control.



                                                                                                                                   SYMBOL
                                                                                                                                   Symmetrical control
                                                                                                                                                  ACB-S                                AC1-S                       CB2-S

                                                                                                                                                   A  B                                   A  B                   A  B
                                                                                                                                             a      0     b                         a                                   b
                                                                                                                                     a                              b       a                     b        a                      b
                                                                                                                                                   P  T                                   P  T                   P  T

                                                                                                                                   Meter-in control
                                                                                                                                                  ADB-V                                AD1-V                       DB2-V

                                                                                                                                                   A  B                                   A  B                   A  B
                                                                                                                                             a            b                         a                                   b
                                                                                                                                    a                               b       a                     b        a                      b
                                                                                                                                                  P  T                                    P  T                   P  T







                                                                                                                                   GENERAL SPECIFICATIONS                               ACTUATION
                                                                                                                                    Designation        Proportional spool valve          Actuation          Proportional solenoid, wet pin push
                                                                                                                                    Construction       Direct operated                                      type, pressure tight
                                                                                                                                    Mounting           Flange construction               Execution          W.E45 / 23 x 50  (Data sheet 1.1-182)
                                                                                                                                    Nominal size       NG6 according to ISO 4401-03                         M.S45 / 23 x 50 (Data sheet 1.1-181)
                                                                                                                                    Actuation          Proportional solenoid             Connection         Connector socket EN 175301 – 803
                                                                                                                                    Ambient temperature  -25…+70 °C                                         Connector socket AMP Junior-Timer
                                                                                                                                                       if >50 °C, I  is only conditionally                  Connector Deutsch DT04 – 2P
                                                                                                                                                              G
                                                                                                                                                       achievable
                                                                                                                                    Weight             1,5 kg (1 solenoid)
                                                                                                                                                       2,0 kg (2 solenoids)







                                                                                                                                                      www.wandfluh.com  Illustrations are not binding  Data subject to change  1/5  Edition: 20 23  1.10-77 E
   361   362   363   364   365   366   367   368   369   370   371