Page 20 - Softbound_Edition_19_en
P. 20

Information Ambient Temperature



                                                                                                                                   Operating and storage temperatures of valves

                                                                                                                                   Wandfluh valves can be used within the temperature ranges listed below.


                                                                                                                                   Limitations

                                                                                                                                   Temperature range:
                                                                                                                                   Limitations, in particular for the maximum permissible temperatures, can have other reasons, independent of the sealing material (e.g., in the Ex-
                                                                                                                                   protection area). Releasing of other values only after consultation.

                                                                                                                                   Performance data:
                                                                                                                                   During operation outside the temperature ranges indicated on the data sheets, the performance data may be limited.



                                                                                                                                    Sealing material     Additional designation  Valve           Operating temperature  Storage temperature
                                                                                                                                    NBR / Acrynitrile    None                Standard            -25°C ... +70°C      -40°C ... +70°C


                                                                                                                                    FKM / Viton          D1                  Standard            -20°C ... +70°C      -40°C ... +70°C


                                                                                                                                                                             Standard with increased
                                                                                                                                    NBR 872 / Acrynitrile  Z604                                  -40°C ... +70°C      -40°C ... +70°C
                                                                                                                                                                             play

                                                                                                                                                                             Valves made of special
                                                                                                                                    PU / Polyurethane    Z591                materials and increased   -60°C ... +70°C  -60°C ... +70°C
                                                                                                                                                                             play



                                                                                                                                   Terms
                                                                                                                                   Operating temperature:
                                                                                                                                   The operating temperature is the ambient temperature and the temperature of the pressure medium and designates the temperature range, within
                                                                                                                                   which the valve may be operated and put into operation.
                                                                                                                                   Storage temperature:
                                                                                                                                   A verage temperature of the ambient of the valve.
                                                                                                                                   Important: This temperature indication also includes the temperature range of the installation in a non-operating condition.