Page 1218 - Softbound_Edition_19_en
P. 1218
Proportional throttle valve Proportional throttle valve
Proportional throttle valve
TYPE CODE ELECTRICAL CONNECTION
D P PM22 - - / M E - HB4,5 # X1 Analog interface (Main) X1 Fieldbus interface (Main)
Throttle valve
Device receptacle M23, 12 pole male Device receptacle M12, 4 pole male
Normally closed N 1 = Supply voltage + 2 1 1 = Supply voltage +
Normally open O 8 9 1 2 = Supply voltage 0 VDC 3 4 2 = Reserved for extentions
7 12 10 2 3 = Stabilised output voltage 3 = Supply voltage 0 VDC
Proportional 6 11 3
5 4 4 = Command value signal voltage + 4 = Chassis
5 = Command value signal voltage -
Screw-in cartridge M22 x 1,5
6 = Command value signal current +
Nominal volume flow rate Q N 6,3 l/min 6,3 7 = Command value signal current -
10 l/min 10 8 = Reserved for extentions
25 l/min 25 9 = Reserved for extentions X2 Parameterisation interface
10 = Enable signal (Digital input) USB, Mini B Under the screw plug of the housing
Nominal voltage U N 12 VDC G12
24 VDC G24 11 = Error signal (Digital output) cover
12 = Chassis Factory set
Slip-on coil Metal housing square Command value signal voltage (PIN 4/5) resp. current (PIN 6/7) are
selected with parameterisation and diagnostics software PASO.
Connection execution Integrated electronics
Hardware configuration
Analog command value signal 12 pole A1 7 pole D1 (0…10 V preset) X1 Analog interface (Main) X3 Profibus interface according to IEC
Analog command value signal 12 pole A4 7 pole D4 (4 … 20 mA preset) Connector DIN EN 175201 - 804 947-5-2
CANopen according to DSP-408 C1 Device receptacle 7 pole male Device receptacle M12, 5 pole female B-coded
Profibus DP according to Fluid Power Technology P1
CAN J1939 (on request) J1 A = Supply voltage + 2 3 1 = VP
A 5
F B B = Supply voltage 0 VDC 1 4 2 = RxD / TxD - N
Function G C = Not connected 3 = DGND
Amplifier E D C D = Command value signal + 4 = RxD / TxD - P
Controller with current feedback value signal (0…20 mA / 4… 20 mA) R1 E = Command value signal - 5 = Shield
Controller with voltage feedback value signal (0 … 10 V) R2
F = Not connected
Sealing material NBR G = Chassis
FKM (Viton) D1
Command value signal: current (D4) or voltage (D2) to specify
when placing the order
Manual override
Design index (subject to change)
2.6-541 X3 CANopen interface according to DRP X4 (controller only) Feedback value interface (sensor)
303-1 Device receptacle M12, 5 pole female
GENERAL SPECIFICATIONS HYDRAULIC SPECIFICATIONS Device receptacle M12, 5 pole male 2 3 1 = Supply voltage (output) +
5
2 1 1 = Not connected 1 4 2 = Feedback value signal +
Designation Proportional throttle valve with Working pressure p = 350 bar 5 2 = Not connected 3 = Supply voltage 0 VDC
max
integrated electronics Maximum volume flow Q = 32 l/min 3 4 3 = CAN Gnd 4 = Not connected
max
Construction Direct operated Volume flow direction 1 → 2 4 = CAN High 5 = Stabilised output voltage
Mounting Screw-in cartridge construction Leakage oil max. 50 cm /min at 350 bar 5 = CAN Low Feedback value signal: current (R1) or voltage (R2) to specify
3
Nominal size M22 x 1,5 according to ISO 7789 Nominal volume flow Q = 6,3; 10; 25 l/min when placing the order
N
Actuation Proportional solenoid range at 10 bar valve pressure drop
Ambient temperature -20…+65 °C Hysteresis ≤ 8 % Note! The mating connector is not included in the delivery
The upper temperature limit is a Fluid Mineral oil, other fluid on request
guideline for typical applications, in Viscosity range 12 mm /s…320 mm /s
2
2
individual cases it may also be higher or Temperature range -25…+70 °C (NBR)
lower. The electronics of the valve limit fluid -20…+70 °C (FKM)
the power in case of a too high Contamination Class 18 / 16 / 13
electronics temperature. More detailed efficiency
information can be obtained from the Filtration Required filtration grade ß 6…10 ≥ 75,
operating instructions „DSV”. see data sheet 1.0-50
Weight 1,0 kg
MTTFd 150 years
www.wandfluh.com Illustrations are not binding Data subject to change 2/6 Edition: 22 46 2.6-541 E www.wandfluh.com Illustrations are not binding Data subject to change 3/6 Edition: 22 46 2.6-541 E