Non-return valves, pilot operated non return valves, shuttle valves, pipe failure valves, drain valves, 3-way shifting valves NG6
Pipe failure valve NG6 for line mounting. The valve is screwed directly into the component which has to be protected. Thread size for port A: male G3/8". For port P: female G1/4" for type RBSG638 or female G3/8" for type RBSW638. This pipe failure valve is available in a straight version and in a 90° version. Housing and banjo bolt are zinc coated.
Pipe failure valve
for installation in pipes
- Qmax = 20 l/min
- pmax = 210 bar
Application
Pipe failure valves are used where loads must be protected against uncontrolled lowering after a line rupture, for exemple in scissor lifts or leveling platforms. Caution: Pipe failure valves are nor suitable for applications where pressure and flow changes rapidly under normal working conditions.