Page 980 - Softbound_Edition_19_en
P. 980

Proportional pressure relief valve
                                                                             Proportional pressure relief valve                                                                                           Proportional pressure relief valve


       TYPE CODE                                                                                                                   ELECTRICAL CONNECTION
                                                             B  V  P  PM33  -     -     /  M  E        -     HB4,5  #               X1                 Analog interface (Main)           X1                 Fieldbus interface (Main)
       Pressure relief valve
                                                                                                                                    Device receptacle  M23, 12 pole male                 Device receptacle  M12, 4 pole male
       Pilot operated                                                                                                                                  1 = Supply voltage +                           2  1  1 = Supply voltage +
                                                                                                                                              8 9  1   2 = Supply voltage 0 VDC                       3 4   2 = Reserved for extentions
       Proportional                                                                                                                          7 12 10 2  3 = Stabilised output voltage                       3 = Supply voltage 0 VDC
                                                                                                                                             6  11 3
                                                                                                                                               5  4    4 = Command value signal voltage +                   4 = Chassis
       Screw-in cartridge M33 x 2
                                                                                                                                                       5 = Command value signal voltage -
       Nominal pressure range p    100 bar   100   275 bar     275                                                                                     6 = Command value signal current +
                        N
                              200 bar      200     350 bar     350                                                                                     7 = Command value signal current -
                                                                                                                                                       8 = Reserved for extentions
       Nominal voltage U      12 VDC       G12                                                                                                                                           X2                 Parameterisation interface
                   N                                                                                                                                   9 = Reserved for extentions
                              24 VDC       G24                                                                                                         10 = Enable signal (Digital input)  USB, Mini B      Under the screw plug of the housing
       Slip-on coil           Metal housing square                                                                                                     11 = Error signal (Digital output)                   cover
                                                                                                                                                       12 = Chassis                                         Factory set
       Connection execution   Integrated electronics                                                                                Command value signal voltage (PIN 4/5) resp. current (PIN 6/7) are
                                                                                                                                    selected with parameterisation and diagnostics  software PASO.
       Hardware configuration
       Analog command value signal   12 pole   A1   7 pole     D1     (0 … 10 V preset)
       Analog command value signal   12 pole   A4   7 pole     D4     (4 … 20 mA preset)
       CANopen according to  DSP-408       C1                                                                                       X1                 Analog interface (Main)           X3                 Profibus interface according to IEC
       Profibus DP according to Fluid Power Technology   P1                                                                                            Connector DIN EN 175201 - 804                        947-5-2
       CAN J1939 (on request)              J1
                                                                                                                                    Device receptacle  7 pole male                       Device receptacle  M12, 5 pole female B-coded
       Function                                                                                                                                        A = Supply voltage +                           2 3   1 = VP
                                                                                                                                                                                                      5
       Amplifier                                                                                                                            F   A  B   B = Supply voltage 0 VDC                       1 4   2 = RxD / TxD - N
       Controller with current feedback value signal (0…20 mA / 4… 20 mA)  R1                                                                   G      C = Not connected                                    3 = DGND
       Controller with voltage feedback value signal (0…10 V)       R2                                                                      E     C
                                                                                                                                                D      D = Command value signal +                           4 = RxD / TxD - P
       Sealing material       NBR                                                                                                                      E = Command value signal -                           5 = Shield
                              FKM (Viton)   D1                                                                                                         F = Not connected
                                                                                                                                                       G = Chassis
       Manual override
                                                                                                                                    Command value signal: current (D4) or voltage (D2) to specify
       Design index (subject to change)                                                                                             when placing the order
       2.3-553

       GENERAL SPECIFICATIONS                              HYDRAULIC SPECIFICATIONS                                                 X3                 CANopen interface according to DRP   X4 (controller only)  Feedback value interface (sensor)
                                                                                                                                                       303-1                             Device receptacle  M12, 5 pole female
       Designation        Proportional pressure relief valve with   Working pressure  p  = 400 bar
                                                                                max
                          integrated electronic             Tank pressure      p T max  = p  + 15 bar                               Device receptacle  M12, 5 pole male                               2 3   1 = Supply voltage (output) +
                                                                                                                                                                                                      5
                                                                                     P
       Construction       Pilot operated                    Nominal pressure   P  = 100 bar, 200 bar, 275 bar, 350 bar                           2 1   1 = Not connected                              1 4   2 = Feedback value signal +
                                                                                                                                                  5
                                                                                                                                                       2 = Not connected
                                                                                                                                                                                                            3 = Supply voltage 0 VDC
                                                                                N
       Mounting           Screw-in cartridge construction   range                                                                                3 4   3 = CAN Gnd                                          4 = Not connected
       Nominal size       M33 x 2 according to ISO 7789     Volume flow range  Q = 5…230 l/min                                                         4 = CAN High                                         5 = Stabilised output voltage
       Actuation          Proportional solenoid             Leakage oil        See characteristics                                                     5 = CAN Low                       Feedback value signal: current (R1) or voltage (R2) to specify
       Ambient temperature  -20…+65 °C                      Hysteresis         ≤ 5 % at optimal dither signal                                                                            when placing the order
                          The upper temperature limit is a   Repeatability     ≤ 3 % at optimal dither signal
                          guideline for typical applications, in   Fluid       Mineral oil, other fluid on request
                          individual cases it may also be higher or   Viscosity range  12 mm /s…320 mm /s                          Note!    The mating connector is not included in the delivery
                                                                                   2
                                                                                            2
                          lower. The electronics of the valve limit   Temperature range   -25…+70 °C (NBR)
                          the power in case of a too high   fluid              -20…+70 °C (FKM)
                          electronics temperature. More detailed   Contamination   Class 18 / 16 / 13
                          information can be obtained from the   efficiency
                          operating instructions „DSV”.
       Weight             1,25 kg                           Filtration         Required filtration grade ß 6…10 ≥ 75,
       MTTFd              150 years                                            see data sheet 1.0-50









                         www.wandfluh.com  Illustrations are not binding  Data subject to change  2/6  Edition: 20 40  2.3-553 E                      www.wandfluh.com  Illustrations are not binding  Data subject to change  3/6  Edition: 20 40  2.3-553 E