Page 962 - Softbound_Edition_19_en
P. 962

Proportional pressure relief valve
                                                                             Proportional pressure relief valve                                                                                           Proportional pressure relief valve


       ACCESSORIES                                         COMMISSIONING                                                           Proportional pressure relief cartridge
       Parameterisation software       See start-up        For DSV amplifiers as a rule no parameter adjustments by the cusot-      ◆  direct operated                                  M22 x 1,5
                                                           mer are required. The plugs have to be connected in accordance with      ◆  Q  = 25 l/min                                    ISO 7789
       Parameterisation cable for interface   Article no. 219.2869  the chapter «Electrical connection».                              p  = 400 bar
                                                                                                                                       max
       USB                                                                                                                          ◆  p max   = 350 bar
       (from plug type A on Mini B, 3 m)                   Controllers are supplied configured as amplifiers. The adjustment of        ◆  N max
       Mating connector (plug female) for analog interface  the mode of control and of the controller are carried out by the custo-
       straight, soldering contact M23, 12 pole  Article no. 219.2330  mer by means of the software adjustment (USB interface, Mini B).  DESCRIPTION                                    APPLICATION
       angled, soldering contact M23, 12 pole  Article no. 219.2331  Further information can be found on: «www.wandfluh.com».      Direct  operated  proportional  pressure  relief  valve  in  screw-in    The electrical remote control in conjunction with process controls
                                                           Free- of charge download of the «PASO» software and the operation
       straight, soldering contact, 7 pole  Article no. 219.2335                                                                   cartridge construction for cavity according to ISO 7789. Good flow   allows  economical  solutions  with  repeatable  processes.  The
                                                           instructions for «DSV» hydraulic valves as well as the operation inst-  capacity  due  to  the  differencial  area  principle,  very  sensitively     screw-in cartridge is perfectly suitable for installation in control
                                                           ructions CANopen Protocol resp. Profibus DP Protocol, with Device
       Flange body / sandwich plate NG4-Mini  Data sheet 2.3-720  Profile DSP-408 for «DSV».                                       adjustable. When the operating pressure adjusted by means of the   blocks and is installed in sandwich-  (vertical stacked systems) and
       Flange body / sandwich plate NG6  Data sheet 2.3-740                                                                        proportional solenoid is reached, the valve opens and connects the   in  flange  plates  (corresponding  data  sheets  in  this  register).  For
                                                                                                                                   protected line with the drain to the tank. The back pressure in T (2)   machining the cartridge cavity in steel and aluminum blocks, cavity
       Flange body / sandwich plate NG10  Data sheet 2.3-760  Note!    The mating connectors and the parameterisation cable        affects the pressure in P (1). For the control, Wandfluh proportional   tools  are  available  (hire  or  purchase).  Please  refer  to  the  data

       Threaded body                   Data sheet  2.9-200          are not part of the delivery. Refer to chapter «Accesso-       amplifiers are available (see register 1.13).        sheets in register 2.13.

       Technical explanations          Data sheet 1.0-100           ries».
       Filtration                      Data sheet 1.0-50
       Attention!  Auxiliary conditions for the cable:                                                                             SYMBOL                                               ACTUATION
               – External diameter 12 pol: 3,5…14,7 mm                                                                                                                                   Actuation          Proportional solenoid, wet pin push
               – External diameter 7 pol: 8…10 mm                                                                                         (T) 2
               – Wire cross section max. 1 mm 2                                                                                                                                                             type, pressure tight
               – Recommended wire cross section:                                                                                                                                         Execution          W.S37 / 19 x 50 (Data sheet 1.1-173)
                             2
               0…25 m = 0,75 mm  (AWG18)                                                                                                                                                                    M.S35 / 19 x 50 (Data sheet 1.1-174)
               25…50 m = 1 mm  (AWG17)                                                                                                                                                   Connection         Connector socket EN 175301 – 803
                            2
                                                                                                                                          (P) 1                                                             Connector socket AMP Junior-Timer
                                                                                                                                                                                                            Connector Deutsch DT04 – 2P
       SURFACE TREATMENT                                   SEALING MATERIAL
       ◆  The cartridge body and the solenoid are zinc-nickel coated  NBR or FKM (Viton) as standard, choice in the type code
       ◆  The electronics housing is made of aluminium.                                                                            TYPE CODE
                                                                                                                                                                                              B  D  P  PM22  -     -     /        -        #
                                                                                                                                    Pressure relief valve
       STANDARDS                                           INSTALLATION NOTES                                                       Direct operated
       Cartridge cavity   ISO 7789                          Mounting type      Screw-in cartridge M22 x 1,5
       CANopen            DRP 303-1                         Mounting position  Any, preferably horizontal                           Proportional
       Profibus DP        IEC 947-5-2                       Tightening torque  M  = 60 Nm Screw-in cartridge                        Screw-in cartridge M22 x 1,5
                                                                                D
       Protection class   EN 60 529                                            M  = 5 Nm knurled nut
                                                                                D
                                                                                                                                                                        20
       Contamination      ISO 4406                                                                                                  Nominal pressure range p    20 bar   100    315 bar     315
                                                                                                                                                     N
                                                                                                                                                           100 bar
                                                                                                                                                                                350 bar

                                                                                                                                                                                            350
       efficiency                                                                                                                                          200 bar      200

                                                                                                                                    Nominal voltage U      12 VDC       G12
                                                                                                                                                N
                                                                                                                                                           24 VDC       G24
                                                                                                                                                           without coil   X5
                                                                                                                                    Slip-on coil           Metal housing round              W
                                                                                                                                                           Metal housing square             M
                                                                                                                                    Connection execution   Connector socket EN 175301-803 / ISO 4400   D
                                                                                                                                                           Connector socket AMP Junior - Timer   J
                                                                                                                                                           Connector Deutsch DT04 - 2P      G
                                                                                                                                    Sealing material       NBR
                                                                                                                                                           FKM (Viton)   D1
                                                                                                                                    Manual override        Manual override                 HB4,5
                                                                                                                                                           Screw plug                      HB0

                                                           Wandfluh AG  Postfach  CH-3714 Frutigen                                  Design index (subject to change)
                                                           Tel. +41 33 672 72 72  Fax +41 33 672 72 12  sales@wandfluh.com          2.3-529

                         www.wandfluh.com  Illustrations are not binding  Data subject to change  6/6  Edition: 20 40  2.3-537 E                      www.wandfluh.com  Illustrations are not binding  Data subject to change  1/3  Edition: 17 43  2.3-539 E
       Page 962