Proportional spool valve pilot operated (integrated electronics, slip-on coil) WVPFA10_90_ME

Proportional valves Proportional spool valve pilot operated (integrated electronics, slip-on coil) WVPFA10_90_ME
Product name Symbol Designation according to Table Type of pilot operation Nominal Voltage UN Hardware configuration Function Sealing Material Request
WVPFA 10-BCA-S-90-ti-G12/MEA2_-_BCA-SPilot oil supply (x) and drain (y) internally12 VDCWith analog command value signal (-10…+10 V preadjusted)AmplifierNBRRequest
WVPFA 10-BCA-S-90-ti-G12/MEA2_-D1BCA-SPilot oil supply (x) and drain (y) internally12 VDCWith analog command value signal (-10…+10 V preadjusted)AmplifierFKM (Viton)Request
WVPFA 10-BCA-S-90-ti-G12/MEA2R1-_BCA-SPilot oil supply (x) and drain (y) internally12 VDCWith analog command value signal (-10…+10 V preadjusted)Controller with current feedback signal (0…20 mA / 4…20 mA) RNBRRequest
WVPFA 10-BCA-S-90-ti-G12/MEA2R1-D1BCA-SPilot oil supply (x) and drain (y) internally12 VDCWith analog command value signal (-10…+10 V preadjusted)Controller with current feedback signal (0…20 mA / 4…20 mA) RFKM (Viton)Request
WVPFA 10-BCA-S-90-ti-G12/MEA2R2-_BCA-SPilot oil supply (x) and drain (y) internally12 VDCWith analog command value signal (-10…+10 V preadjusted)Controller with voltage feedback value signal (0…10 V)NBRRequest
WVPFA 10-BCA-S-90-ti-G12/MEA2R2-D1BCA-SPilot oil supply (x) and drain (y) internally12 VDCWith analog command value signal (-10…+10 V preadjusted)Controller with voltage feedback value signal (0…10 V)FKM (Viton)Request
WVPFA 10-BCA-S-90-ti-G12/MEA4_-_BCA-SPilot oil supply (x) and drain (y) internally12 VDCWith analog command value signal (4…20 mA)AmplifierNBRRequest
WVPFA 10-BCA-S-90-ti-G12/MEA4_-D1BCA-SPilot oil supply (x) and drain (y) internally12 VDCWith analog command value signal (4…20 mA)AmplifierFKM (Viton)Request
WVPFA 10-BCA-S-90-ti-G12/MEA4R1-_BCA-SPilot oil supply (x) and drain (y) internally12 VDCWith analog command value signal (4…20 mA)Controller with current feedback signal (0…20 mA / 4…20 mA) RNBRRequest
WVPFA 10-BCA-S-90-ti-G12/MEA4R1-D1BCA-SPilot oil supply (x) and drain (y) internally12 VDCWith analog command value signal (4…20 mA)Controller with current feedback signal (0…20 mA / 4…20 mA) RFKM (Viton)Request
WVPFA 10-BCA-S-90-ti-G12/MEA4R2-_BCA-SPilot oil supply (x) and drain (y) internally12 VDCWith analog command value signal (4…20 mA)Controller with voltage feedback value signal (0…10 V)NBRRequest
WVPFA 10-BCA-S-90-ti-G12/MEA4R2-D1BCA-SPilot oil supply (x) and drain (y) internally12 VDCWith analog command value signal (4…20 mA)Controller with voltage feedback value signal (0…10 V)FKM (Viton)Request
WVPFA 10-BCA-S-90-ti-G12/MEC1_-_BCA-SPilot oil supply (x) and drain (y) internally12 VDCWith CANopen according to DSP-408AmplifierNBRRequest
WVPFA 10-BCA-S-90-ti-G12/MEC1_-D1BCA-SPilot oil supply (x) and drain (y) internally12 VDCWith CANopen according to DSP-408AmplifierFKM (Viton)Request
WVPFA 10-BCA-S-90-ti-G12/MEC1R1-_BCA-SPilot oil supply (x) and drain (y) internally12 VDCWith CANopen according to DSP-408Controller with current feedback signal (0…20 mA / 4…20 mA) RNBRRequest
WVPFA 10-BCA-S-90-ti-G12/MEC1R1-D1BCA-SPilot oil supply (x) and drain (y) internally12 VDCWith CANopen according to DSP-408Controller with current feedback signal (0…20 mA / 4…20 mA) RFKM (Viton)Request
WVPFA 10-BCA-S-90-ti-G12/MEC1R2-_BCA-SPilot oil supply (x) and drain (y) internally12 VDCWith CANopen according to DSP-408Controller with voltage feedback value signal (0…10 V)NBRRequest
WVPFA 10-BCA-S-90-ti-G12/MEC1R2-D1BCA-SPilot oil supply (x) and drain (y) internally12 VDCWith CANopen according to DSP-408Controller with voltage feedback value signal (0…10 V)FKM (Viton)Request
WVPFA 10-BCA-S-90-ti-G12/MEJ1_-_BCA-SPilot oil supply (x) and drain (y) internally12 VDCWith Profibus DP according to Fluid Power TechnologyAmplifierNBRRequest
WVPFA 10-BCA-S-90-ti-G12/MEJ1_-D1BCA-SPilot oil supply (x) and drain (y) internally12 VDCWith Profibus DP according to Fluid Power TechnologyAmplifierFKM (Viton)Request